Watch our two-minute video below to see how KEPServerEX solves common connectivity challenges-providing secure and reliable access to real-time industrial data so everyone from the shop floor to the top floor can make smarter decisions. The platform is developed and tested to meet our customers’ performance, reliability, and ease-of-use requirements. KEPServerEX leverages OPC (the automation industry’s standard for interoperability) and IT-centric communication protocols (such as SNMP, ODBC, and web services) to provide users with a single source for industrial data.
#Kepware opc server manual software
The platform design allows users to connect, manage, monitor, and control diverse automation devices and software applications through one intuitive user interface.
This VI can connect to any OPC Server using DataSocket connection.\National Instruments\LabVIEW 6\examples\comm folder. Launch LabVIEW and open opc.llb in the.
#Kepware opc server manual how to
The following is a brief example of how to connect to RSLinx OPC Server from LabVIEW using our example VI. To learn more about DataSocket, visit Integrating the Internet into
The API provides an interface for different data types, converting the data into a stream of bytes that can be sent across a network via TCP/IP. DataSockets have an OPC layer, allowing you to read and write to an OPC Server from LabVIEW (or LabWindows/CVI).ĭataSocket is a technology based on TCP/IP composed of two elements: the DataSocket API and the DataSocket server. LabVIEW itself is not an OPC Client, but it can be used to communicate to OPC Servers through the DataSocket VIs. The cable model number used was 1761-CBL-PM02. This document was created using RSLinx 2.20.01.107.01, Allen Bradley MicroLogix 1500 PLC, ServerExplorer 2.4.1, Lookout 4.5 and the LabVIEW DSC module 6.0.2. Designed around the four product pillars of Proven Interoperability, Centralized Communications, On-Demand Scalability, and.
#Kepware opc server manual full version
If you decide to use the LabVIEW DDE VIs, then you need to have the full version of RSLinx. KEPServerEX leverages OPC (the automation industrys standard for interoperability) and IT-centric communication protocols (such as SNMP, ODBC, and web services) to provide users with a single source for industrial data. The drawback of DDE connection is that it is slower than OPC. The DDE server is only available for Rockwell Automation DDE clients in the OEM version. Other Allen Bradley PLCs can be used on the OPC server by manually adding the addresses to be seen.Īnother mechanism of communication between applications and RSLinx is through the DDE server that comes with RSLinx. RSLinx 2.0 to 2.20 OPC servers only support the browsing capability on Control Logix 5000 series PLCs. RSLinx OPC server is an in-process type of server, which means that you have to load a DLL to communicate with it. The OPC server is available only with the OEM version or the full version, so the lite version of RSLinx does not have the OPC Server included. Rockwell Automation RSLinx 2.10 is an OPC server, meaning that any OPC Client should be able to exchange data with this server. This version has been upgraded to version 2.20. Rockwell Automation developed their own OPC Server in version 2.0 of RSLinx. Any OPC client, such as Lookout, BridgeVIEW, or other packages on the market, can connect to this server. With the release of Industrial Automation Server CD 1.1, this server became an OPC server.
#Kepware opc server manual driver
The NI Industrial Automation Servers CD has an Allen Bradley (RSLinx) driver that can communicate with RSLinx through a dynamic link library (DLL).